INFRALAN® Cat.7A Installation Cable S/FTP 1250 MHz, CPR Cca
Cable silicone free | PoE | Cable structure | Category | Conductor category | Conductor material | AWG-size/quantity of cores | Diameter conductor | Screen over stranding | Stranding element | Screen over stranding element | Core insulation | Core identification | Material outer sheath | Euro class | Flame retardant | Halogen free | Low smoke | Operating temperature, flexible | Operating temperature, fix | Operating temperature, storage | Bending radius (dynamic) | Bending radius (static) | NVP value | Loop resistance | Resistance unbalance | Dielectric strength DC | Insulation resistance (500V) | Capacity to earth | Impedance | Transfer impedance at 1MHz | Transfer impedance at 10MHz | Transfer impedance at 30MHz | Transfer impedance at 100MHz | Separation class acc. EN50174-2 | Coupling attenuation Type | Coupling attenuation | Cabling standards | Installation standard | Harmonised Standard | Directive/Regulation | Transmission standards | Cable | Max. Freuqency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
yes | yes;PoE+ | S/FTP | 7A | Kl.1 = single wire | Cu, tinned | 23/1 | 0.56mm | braiding | pairs | foil | foam-skin PE | colour | FRNC | Cca | acc. EN 60332-1 | acc. EN 60754-1/2 | acc. to EN 61034-2 | 0 – 50°C | -20 – 60°C | 0 – 50°C | ≥ 60mm | ≥ 30mm | 78% | ≤ 140Ohm/km | ≤ 2% | 1kV/1 min | ≥ 5000MOhm/km | ≤ 1600pF/km | 100 ± 5Ohm | ≤ 10mOhm/m | ≤ 10mOhm/m | ≤ 20mOhm/m | ≤ 30mOhm/m | D | Typ 1b | ≥ 80dB | ISO/IEC 11801;EN 50173-1 | EN 50174 | EN 50575 | RoHS 2011/65/UE;REACH 1907/2006/EC | IEEE 802.3 10Mbit bis 10Gbit | IEC 61156-5;EN 50288-9-1 | 1250MHz |
Article information
The INFRALAN® installation cable 99985.x-CPR is constructed for transmissions up to 1250 MHz and exceeds with the electrical transmission properties and requirements of the category 7A. Suitable for structured cabling of Class E, EA, F and FA according to ISO/IEC 11801 (AMD 2:2009) resp. EN 50173-1 (2009). With this cable transmission rates up to 10 GBit according to IEEE 802.3 are possible.
Variants
Article No. | Planers text | Title | Price (SRP) | Length | Colour outer sheath | RAL colour | Number of cores | Type | Outer diameter approx. | Copper weight | Weight | Max. tractive force | Fire load |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
99985.1-CPR | INFRALAN® Cat.7A 1250 AWG23 S/FTP 4P CPR Cca rape yellow RAL1021 | 1,05 | 1.0m | rape yellow | RAL1021 | 8 | simplex | 7.7mm | 32kg/km | 62kg/km | 95N | 0.64MJ/m | |
99985.500-CPR | INFRALAN® Cat.7A 1250 AWG23 S/FTP 4P CPR Cca rape yellow RAL1021, 500m | 540,74 | 500.0m | rape yellow | RAL1021 | 8 | simplex | 7.7mm | 32kg/km | 62kg/km | 95N | 0.64MJ/m | |
99985.100-CPR | INFRALAN® Cat.7A 1250 AWG23 S/FTP 4P CPR Cca rape yellow RAL1021, 100m | 100.0m | rape yellow | RAL1021 | 8 | simplex | 7.7mm | 32kg/km | 62kg/km | 95N | 0.64MJ/m | ||
99985DX.500-CPR | INFRALAN® Cat.7A 1250 AWG23 S/FTP 2x4P CPR Cca rape yellow RAL1021, 500m | 1032,13 | 500.0m | rape yellow | RAL1021 | 2x8 | duplex | 7.7 x 16.1mm | 64kg/km | 124kg/km | 190N | 1.28MJ/m | |
99985DX.1-CPR | INFRALAN® Cat.7A 1250 AWG23,S/FTP 2x4P CPR Cca rapsgelb RAL 1021 | 1.0m | rape yellow | RAL1021 | 2x8 | duplex | 7.7 x 16.1mm | 64kg/km | 124kg/km | 190N | 1.28MJ/m |